ELSR-N-AO/BO/BOT up to 80 °C

Applications

  • Frost protection
  • Heat tracing on level indicators
  • Chemical & petrochemical industries
  • Pipe heat tracing
  • Vessels and tanks
  • Automotive
  • Food processing industry

Technical Details

  • Outer jacket: TPE-O
  • Bus wire: nickel plated copper
  • Maximum exposure temperature (power off): 80 °C
  • Maximum exposure temperature (power on): 65 °C
  • Nominal voltage: 230 V
  • Bending radius, minimum: 25 mm
  • Installation temperature, min.:– 45 °C
  • Classification: II 2G Ex e IIC Gb II 2D Ex tb IIIC Db
  • Certificates: IECEx EPS 12.0006U, 12ATEX1431U
  • Nominal output: 10 / 20 / 30 / 40 W/m at 10 °C

ELSR-LS-AO/BO up to 80 °C

Applications

  • Pipe heat tracing
  • Frost protection for industrial applications
  • Temperature maintenance for pipes and vessels
  • Chemical & petrochemical industries
  • Paints & varnishes
  • Automotive
  • Food processing industry

Technical Details

  • Outer jacket: TPE-O
  • Bus wire: 1.23 mm² nickel plated copper
  • Maximum exposure temperature (power off): 80 °C
  • Maximum exposure temperature (power on): 65 °C
  • Nominal voltage: 230 V
  • Bending radius, minimum: 25 mm
  • Installation temperature, min.:– 50 °C
  • Classification: II 2G Ex e IIC Gb II 2D Ex tb IIIC Db
  • Certificates: IECEx EPS 12.0006U 12ATEX1431U
  • Nominal output: 10 / 15/ 25 / 30 W/m at 10 °C

ELSR-M-BO/AO up to 65 °C, ELSR-M-AF/BF up to 65 °C, for use in potable water

Applications

  • Heat tracing on pipes, pumps and valves
  • Food processing industry
  • Automotive
  • Heating of tube bundle cables for water analysis
  • Heat tracing on vessels
  • Internal trace heating for pipes and hoses (ELSR-M-BF/AF only)

Technical Details

  • Outer jacket: TPE-O
  • Bus wire: Nickel plated copper
  • Maximum exposure temperature (power off): 65 °C
  • Maximum exposure temperature (power on): 65 °C
  • Nominal voltage: 230 V
  • Bending radius, minimum : 25 mm
  • Installation temperature, min.: – 45 °C
  • Certificates: K-229437-13-Bs/st (for use in potable water, only ELSR-M-BF/AF)
  • Nominal output: 10 / 15 W/m at 10 °C (ELSR-M-BF/AF 10 W/m at 10 °C )

ELSR-R-BOT up to 65 °C

Applications

  • Frost protection for doors and seals of refrigerating chambers
  • Usage in cooling water lins of breweries and drink manufacturers

Technical Details

  • Outer jacket: fluoropolymer
  • Bus wire: Nickel plated copper
  • Maximum exposure temperature (power off): 65 °C
  • Maximum exposure temperature (power on): 65 °C
  • Nominal voltage: 230 V
  • Bending radius, minimum: 30 mm
  • Installation temperature, min.: – 30 °C
  • Nominal output: 19 / 27 W/m at 10 °C

ELSR-W-AO/BO up to 100 °C

Applications

  • Food processing industry
  • Heat tracing on fat lines
  • Drainage lines in canteens and large-scale kitchens
  • Frost protection for heating lines
  • Installation on hot water supplies to prevent Legionella formation

Technical Details

  • Outer jacket: TPE-O
  • Bus wire: Nickel plated copper
  • Maximum exposure temperature (power off): 100 °C
  • Maximum exposure temperature (power on): 80 °C
  • Nominal voltage: 230 V
  • Bending radius, minimum : 20 mm
  • Installation temperature, min.: – 20 °C
  • Nominal output: 55 / 65 W/m at 10 °C

ELSR-H-BOT up to 210 °C

Applications

  • Chemical & petrochemical industries
  • Oil & gas industry
  • Power plants
  • Hazardous locations
  • Frost protection
  • Water & sanitation utilities
  • Temperature maintenance on vessels, pipes & valves

Technical Details

  • Outer jacket: Fluoropolymer
  • Bus wire: Nickel plated copper
  • Maximum exposure temperature (power off): 210 °C
  • Maximum exposure temperature (power on): 120 °C
  • Nominal voltage: 230 V / 120 V*
  • Bending radius, minimum : 25 mm
  • Installation temperature, min.: – 45 °C
  • Classification: II 2G Ex e IIC Gb II 2D Ex tb IIIC Db
  • Certificates: IECEx EPS 12.0004 12ATEX1429U
  • Nominal output: 10/15 / 20 / 30 / 45 / 60 W/m at 10 °C

*upon request