控制和检测

A detailed analysis of all parameters at the installation site is required to ensure the highest energy saving and the lowest life-cycle costs. Besides weather data, available connecting loads as well as customer-specific data like travel and maintenance periods are included in the concept.

The individual concept of a control system can be integrated in an overall concept with various interlinked components. Both the connection to a visualisation system as well as the integration in existing higher-level control devices and condition-monitoring systems are possible at any time.

Depending on configuration, the following data will be processed in the logic:

  • Actual power consumption
  • Energy consumption per day / week / month / year
  • Status signal of all heating circuits available
  • Energy storage
  • Power supply data (power / current / energy)
  • Error messages
  • Warning messages to ensure preventive maintenance works
  • Weather data: wind direction and speed, precipitation type and quantity, air and rail temperature

eltherm systems do more than just trigger heating. They also monitor the complete system and detect errors – if any.


Technical options:

  1. Nominal voltages from 24 V up to 1000 V AC and DC, supply via local network or overhead line
  2. Stand-alone or connection to the control system through glass fibre or copper wires (GSM, GSM-R, Tetra, etc) – mixed operation of different medias possible
  3. Control cabinet systems made of steel, stainless steel, aluminum sheet or glass fiber reinforce plastic (GRP) in protection classes up to IP 68 K
  4. Surge protection systems
  5. Evaluation of weather forecasting services to ensure a timely preheating of facilities

Server Based Control System

The central server offers several benefits:

  • Central modem pool
  • All alarms are sent to one place
  • All alarms are stored in the same database
  • Alarms can be rerouted into e-mails, SMS messages via server
  • All software is stored in one place, which means easy maintenance, upgrades and back-up routines
  • Customised user rights management

 

Server based control system


2017-06-07T16:13:23+00:00