ELW-GN up to 260 °C
Applications
- Heat tracing on apparatus, appliances and systems
- Devices and systems made of glass with sensitive surfaces
- Laboratory applications
Technical Information
- Insulation: Fluoropolymer
- Protective braid: Nickel-plated copper
- Outer jacket: E-glass textile
- Nominal voltage: 230 V
- Output Approx.: 50 W/m*
- Operating temp., max.: 260 °C
- Dimensions (wxh) Approx.: 25 x 6 mm
- Bending radius, flat, min.: 10 mm
- Installation temp., min.: -60 °C
- Moisture proof
- Cold lead length,both ends: 1.2 m, without plug
- Protection class: I
- Manufactured according to: DIN VDE 0253
- Final inspection according to: DIN VDE 0721 T411 2.5 kV AC – 1 min
ELW-VA up to 260 °C, for corrosive environment
Applications
- Heat tracing on apparatus, appliances and systems
- Laboratory applications
- Temperature maintenance on piping
Technical Information
- Insulation: Fluoropolymer
- Protective braid: 1.4301 / SS 304
- Nominal voltage: 230 V
- Output approx.: 50 W/m*
- Operating temp., max.: 260 °C
- Dimensions (wxh) Approx.: 10 x 5 mm
- Dimensions, sleeve (wxhxl): 32 x 16 x 65 mm
- Bending radius, flat, min.: 15 mm
- Installation temp., min.: -30 °C
- Moisture proof
- Cold lead length, both ends: 1.2 m, silicone cable, without plug
- Protection class: I
- Manufactured according to: DIN VDE 0253
- Final inspection according to: DIN VDE 0721 T411 2.5 kV AC – 1 min
ELW-H up to 450 °C
Applications
- Heat tracing on apparatus, appliances and systems made of glass, quartz or ceramic material
- Glass devices and systems with high output needs
- Laboratory & research applications
Technical Information
- Insulation: E-glass textile
- Outer jacket: E-glass textile
- Nominal voltage: 230 V
- Output approx.: 250 W/m*
- Operating temp., max.: 450 °C
- Dimensions: 30 x 5 mm
- Bending radius, flat, min.: 10 mm
- Installation temp., min.: Not restricted
- Connection: 1.2 m, without plug
- Protection class: Depending on installation
- Manufactured according to: DIN VDE 0721 T2
- Final inspection according to: DIN VDE 0721 T411 1.5 kV AC – 1 min
ELW-HS up to 450 °C
Applications
- Heat tracing on apparatus, appliances and systems made of glass, quartz or ceramic material
- Glass devices and systems with high output needs
- Laboratory & research applications
Technical Information
- Insulation: E-glass textile
- ctive braid: 1.4301 / SS 304
- Outer jacket: E-glass textile
- Nominal voltage: 230 V
- Output approx.: 250 W/m*
- Operating temp., max.: 450 °C
- Dimensions: 30 x 5 mm
- Bending radius, flat, min.: 10 mm
- Installation temp., min.: Not restricted
- Connection: 1.2 m, without plug
- Protection class: I
- Manufactured according to: DIN VDE 0721 T2
- Final inspection according to: DIN VDE 0721 T411 1.5 kV AC – 1 min
ELW-Q up to 900 °C
Applications
- Heat tracing on glass, quartz and ceramic devices
- Devices and systems with highest output needs
- Laboratory & research applications
Technical Information
- Insulation: Quartz textile
- Outer jacket: Quartz textile
- Nominal voltage: 230 V
- Output: 350 W/m*
- Operating temp., max.: 900 °C
- Dimensions (wxh) Approx.: 35 x 6 mm
- Bending radius, flat, min.: 20 mm
- Installation temp., min.: Not restricted
- Cold lead length: 1.2 m, without plug
- Manufactured according to: DIN VDE 0721 T2
- Final inspection according to: DIN VDE 0721 T2 1.5 kV AC – 1 min
*Note: The output per meter of heating cable and the maximum possible operating temperatures depend on the respective application. For individual cases, we recommend that you contact our engineers – we will be pleased to advise you.